MICRODUST pro
Aerosol Monitoring System
WINDUST pro
Application Software
Users Handbook
HB3275-06
COPYRIGHT
Vista de pagina 0
1 2 3 4 5 6 ... 58 59

Indice de contenidos

Pagina 1 - Users Handbook

MICRODUST proAerosol Monitoring SystemWINDUST proApplication SoftwareUsers HandbookHB3275-06COPYRIGHT

Pagina 2 - New with Firmware Version 06

EnterEscCASELLAMICRODUST proAerosol Monitoring SystemEscEnterv30053Pull the knurledsleeve outwardsto release theconnectorRed dotSlide theProbe Collaru

Pagina 3 - WARNINGS !

1.4 Analogue Output/RS 232 SocketEsc00018642531Description

Pagina 4 - GETTING STARTED

Ω1.5 Schedule of Partsv30054CASELLAMICRODUSTproAerosolMonitoringSystemEscEnter02055Slide toUnlockDescription

Pagina 5 - TABLE OF CONTENTS

2. OPERATION2.1 Preparation for Use2.1.1 Power SupplyWarning !0001312 V DCPowerRS 232ClipTripod BushIrDA (NotImplemented)Lift EndoReleaseCoverSlide Of

Pagina 6 - TABLE OF CONTENTS (Continued)

Serial Number LabelBoot ModeNormallyDisabledChargerEnableFactorySettings00014ON12Warning !2.1.2 Sampling Probe*2.1.3 Supporting the InstrumentOperatio

Pagina 7 - 1.1 Introduction

2.2 Preliminary Operations2.2.1 Switching ON and OFFØ.Ø26AveMaxmg/m3Ø.ØØ61.8Ø6Cal:- DEFAULTMP02Enter3.00.001.81Ø mg/m31ØØsecMP03Operation

Pagina 8 - 1.2 Principle of Operation

2.2.2 Checking Battery Status & Firmware Version2.2.3 Configuring for the Current MeasurementEsc**MAIN MENU**View GraphView GraphView MeasurementM

Pagina 9 - MicroDust Measurement mg/m

EnterCONFIGURATIONMeasuring RangeAveraging TimeBack LightTime & DateLanguageSerial Comm'sMP12EnterEnterEnterOperation

Pagina 10 - Description

EnterEnterAVERAGING TIMEAverage: 1SecAveØffØ.5ØØKeypadAnalogue:Alarm Status:Alarm Level:Alarm Reset:MP30Operation

Pagina 11

EnterEnterEnterOperation

Pagina 12 - 1.5 Schedule of Parts

New with Firmware Version 06

Pagina 13 - 2.1 Preparation for Use

EnterEnterSET TIMEHours:Minutes: Ø1Seconds: 3215MP18SET DATEDate:Day:Month: MarchYear: ØØ14WednesdayMP19EnterEnterSerial CommsPort: RS 232Baud Rate: 9

Pagina 14 - 2.1.2 Sampling Probe*

2.3 Calibration2.3.1 Checking Zero and SpanEnterCALIBRATIONSet ZeroSet SpanSet Optical FilterUser Dust TypesRestore Default CALMP21Operation

Pagina 15 - 2.2.1 Switching ON and OFF

EnterEnterPurge BellowsCalibrationFilter00023Operation

Pagina 16 - Operation

2.3.2 Calibrating for a Specific Dust TypeEnterEnterEnterOperation

Pagina 17

Operation

Pagina 18

2.3.3 Applying the Calibration√√CorrectionFactorGravimetric ConcentrationInstrument Average ading T W A=Re ( . . )Dust Name OPTØ] DEFAULT1] LIMESTONE2

Pagina 19

2.4 Measurement2.4.1 Maximum Value (Max.)EnterSET DUST PARAMETERSDust:SITE 4Factor: 1.ØØØSet Factor:Set Name:MP27EnterEnterEnterOperation

Pagina 20

2.4.2 Time Weighted Average Value (Ave)2.5 Data Logging2.5.1 Configuring the LoggerMP07CONFIG LOGGERIntervals: SecØØ1Stop when fullClear Memory: NOLog

Pagina 21 - 2.3.1 Checking Zero and Span

2.5.2 Clearing the Logger Memory2.5.3 Start LoggingEnterEnterLOGGERView RunsConfig LoggerStart LoggerMP06EnterØ.Ø26AveMaxmg/m3Ø.ØØ61.8Ø6Cal:- DEFAULT2

Pagina 22 - Calibration

Time:Start Date:16:1Ø:57Ø8 Mar ØØØ1/Ø2Run Number:Duration: Ø1:29:44Ave Value:Max Value: 25.ØØ4.37MP08Operation

Pagina 23

WARNINGS !UNDER NO CIRCUMSTANCES should this instrument becleaned using a solvent based cleaner.Attempts to charge non-rechargeable cells is hazardous

Pagina 24

Operation

Pagina 25 - Re ( . . )

3. WINDUST pro APPLICATION SOFTWAREApplications¤¤¤¤¤¤¤¤3.1 Installation on Windows 95™, 98™, ME™,Windows NT™ & Windows 2000™Start Run…ApplicationS

Pagina 26 - 2.4.1 Maximum Value (Max.)

a:\setupEnter3.2 Starting WinDust proOK3.3 Profiles3.3.1 Creating/Editing a ProfileProfiles EditNew EditInstrument.bmpApplicationSoftware

Pagina 27 - 2.5.1 Configuring the Logger

ProCommunicationsCommsPortComms via amodemModemDialApplicationSoftware

Pagina 28

Data FilesFile PrefixOK3.3.2 Sending a Profile to the InstrumentSend Profile CommsApplicationSoftware

Pagina 29

3.4 Downloading Data from the LoggerDownload Comms3.5 Presentation of DataPrint FileFile Print PreviewCopy EditFont Edit3.5.1 Displaying the Data Summ

Pagina 30

Open FileSummary ViewApplicationSoftware

Pagina 31 - Start Run…

3.5.2 Displaying Data as a GraphGraph ViewApplicationSoftware

Pagina 32 - 3.3 Profiles

3.5.3 Displaying Data as a TableTable View3.5.4 Exporting Data to Other Applications.datApplicationSoftware

Pagina 33 - Software

3.6 Real-Time Display ModeReal Time CommsResetApplicationSoftware

Pagina 34 - Send Profile Comms

GETTING STARTEDIt is suggested that you prepare, calibrate and operateyour MicroDust pro following the sequence of sections inthe Operations Chapter:P

Pagina 35 - 3.5 Presentation of Data

Re-scaleAuto ScaleAuto Scale3.7 Gravimetric Correction by WinDust proSoftwareApplicationSoftware

Pagina 36 - Summary View

Calibration EditOKYes.datApplicationSoftware

Pagina 37 - Graph View

ApplicationSoftware

Pagina 38 - Table View

4. SAMPLING ACCESSORIES4.1 Gravimetric AdaptersSamplingAccessories

Pagina 39 - 3.6 Real-Time Display Mode

4.2 TSP / Respirable AdaptersPump Connectionø37 mm Filter Holder00026"O" Ring"O" RingAdapterLocating SpigotInlet Tube Complete&quo

Pagina 40

4.3 PUF Filter AdapterPump Connection00027ø37 mm Filter Holder"O" Ring"O" RingLocating SpigotPUF Filter HolderPM /Respirable10ø25

Pagina 41 - Calibration Edit

Storage of PUF FiltersInserting / Removing PUF FiltersPUF Filter Spares List4.4 Aspirator UnitSamplingAccessories

Pagina 42

Fan Aspirator'O' Ring'O' RingAdapterLocating Spigot'O' RingInlet Tube CompleteThumb ScrewMeasuringChamberMicroDustProbe0

Pagina 44 - 4.2 TSP / Respirable Adapters

5. MAINTENANCE & SERVICING5.1 Service Department5.2 Lens Contamination5.2.1 Long Term MonitoringMaintenance& Servicing

Pagina 45 - 4.3 PUF Filter Adapter

TABLE OF CONTENTSContents

Pagina 46 - 4.4 Aspirator Unit

5.2.2 Cleaning5.3 Fault Finding TipsMaintenance& Servicing

Pagina 47 - Accessories

6. SPECIFICATION6.1 Instrument SpecificationMeasurementµPower SupplySpecification

Pagina 48

Physical∅Displayed ValuesData LoggerSpecification

Pagina 49 - 5.2 Lens Contamination

Ω6.2 Maintenance6.3 WinDust pro, PC Based Application Software6.4 Spare Parts6.5 Optional Accessories6.6 CE ComplianceSpecification

Pagina 51 - 6.1 Instrument Specification

APPENDIX AMicrodust pro Remote Control Command SetA.1 IntroductionA.2 Individual CommandsCommand ‘X’: - Start real time outputAppendix A

Pagina 52 - Data Logger

Command ‘Z’: - Stop real time outputCommand ‘I’: - Interrogate targetCommand ‘T’: - Download records storedCommand ‘R’: - Set instrument id and time d

Pagina 53 - 6.6 CE Compliance

Command ‘B’: - Upload bitmap screen to instrumentCommand ‘C’: - Clear bitmapUser interface CommandsDisplayMICRODUST proAerosol Monitoring SystemEscEnt

Pagina 55 - APPENDIX A

ProMICRODUSTSerial CommsPort: RS 232Baud Rate: 96ØØData Bits: 8Stop Bits: 1Parity: NoneMICRODUST proMenu StructurePress to Zerostable.Purge Probe unti

Pagina 56 - Appendix A

TABLE OF CONTENTS (Continued)Contents

Pagina 57

1. DESCRIPTION OF THE MICRODUST pro1.1 IntroductionDescription

Pagina 58

¤¤¤¤1.2 Principle of OperationInfra RedEmitterInfra RedDetectorSampleVolumeLight Stop00009Description

Pagina 59 - Menu Structure

1.3 The MicroDust pro Menu StructureGravimetric Measurement mg/m3MicroDust Measurement mg/m3005001000150020002500500 1000 1500 2000 2500Linear Best Fi